In October 2026, the Heat and Mass Transfer Academic Conference of the Chinese Society of Engineering Thermophysics was held in Xi’an. Revealer attended with its PIV measurement systems and high-speed cameras, engaging with researchers on image acquisition and quantitative measurement needs in experiments involving gas–liquid interfaces, gas jets, and multiphase flows.
Figure 1 — Opening presentation at the Heat and Mass Transfer Academic Conference of the Chinese Society of Engineering Thermophysics
As a bubble approaches a surface, how is the surrounding liquid displaced? Under an applied magnetic field, how does the velocity distribution of a gas jet change? During sono-electrocoagulation treatment, how do flow disturbances affect particle aggregation? These questions all require linking visible morphological changes to local flow.
The representative cases below center on bubble capture, magnetically modulated jets, and particle flocculation, all using Revealer high-speed cameras to acquire PIV images. Among them, the sono-electrocoagulation flocculation study used Revealer’s PIV flow measurement software RFlow4 for computation and analysis. These cases show how PIV flow measurement can be combined with interface observation, particle characterization, and numerical computation to support the analysis of transport processes.
In experiments capturing rising bubbles on superhydrophobic surfaces, high-speed imagery can identify bubble approach, deformation, and coalescence. To explain why different surfaces exhibit different capture behaviors, it is also necessary to observe the liquid motion near the bubble and how the surrounding vortex structures evolve.
In a study published in *Nature Communications* by a research team from Shanghai Jiao Tong University and other institutions, a superhydrophobic surface consisting of micropillar arrays decorated with nanoparticles was constructed. The study used a Revealer X190 high-speed camera at 9,000 fps to record the bubble capture process; in the PIV experiments, particle images were acquired at 4,000 fps and velocity fields computed.
The researchers added polyamide seeding particles of approximately 20 μm diameter to the water and illuminated the flow near the bubble with a laser sheet. The study compared velocity-colored streamlines for micropillar aspect-ratio parameters (b/a) of 0.3, 1.7, and 3.5. The results show that as the bubble rises, liquid between the bubble and the micropillar surface is expelled outward; at larger (b/a), the vortex structures on both sides of the bubble and in its wake intensify, and the velocity distribution below the bubble changes. These differences allow a concrete comparison of the link between micropillar geometry parameters and the motion of the adjacent liquid.
By combining the capture process recorded by high-speed imaging, interfacial deformation observation, and numerical analysis, the study linked rapid capture to gas-layer deformation, liquid-film drainage, and local rupture. The surrounding flow-field information provided by piv measurement supplied experimental evidence for analyzing how liquid responds to micropillar structural changes during bubble approach.
Figure 2 — PIV streamline distributions of the surrounding liquid as a rising bubble approaches the superhydrophobic surface under different micropillar aspect ratios, with streamline color indicating velocity magnitude.
While the bubble experiment explains liquid motion near the interface through local velocity fields, PIV can likewise compare velocity distributions before and after changing external conditions when the object of study is a gas jet, and provide experimental validation for numerical models.
Flame variation under magnetic fields involves multiple coupled processes including flow, heat transfer, and chemical reaction. A research team from Southeast University investigated non-reacting gas jets to exclude the influence of heat release and chemical reactions, isolating the effect of a gradient magnetic field on gas motion. The related results were published in *International Communications in Heat and Mass Transfer*.
The study used titanium dioxide particles of 1–2 μm diameter as tracer particles, illuminated by a 532 nm continuous laser, with PIV images acquired by a Revealer X213 high-speed piv camera. By adjusting the electromagnet current to change the field conditions, the experiment compared jet structures under different operating conditions.
Figure 3 presents the axial velocity distributions at a nitrogen outlet mean velocity of 66.31 cm/s; the left side of each panel shows the PIV experimental result and the right side the numerical result. Compared with the no-field condition, at 10 A the height of the jet core region decreases slightly and the jet width narrows; at 20 A, the upstream extension range of the jet is markedly shortened.
PIV measurement grounds the evaluation of magnetic-field effects in velocity changes at specific locations, which can be compared with computational results at the same cross-sections. Such comparison helps verify whether the model reproduces the position and dimension changes of the jet core region.
Figure 3 — Axial velocity distributions at different electromagnet currents for a nitrogen outlet mean velocity of 66.31 cm/s; the left side of each panel shows PIV results and the right side numerical results, at currents of 0, 10, and 20 A.
The jet case compares the influence of external fields on flow through velocity distributions. In liquids containing bubbles and suspended particles, flow is also related to particle collision, aggregation, and settling, requiring the flow-field results to be analyzed jointly with particle size and surface property information.
In ultrasound-assisted electrocoagulation, ultrasonic disturbances, bubbles generated by electrolysis, and particle aggregation jointly affect the flow. Enhanced flow favors particle contact, while local disturbances may compromise floc stability. Evaluating treatment performance requires simultaneously understanding changes in both the flow field and particle state.
In a study published in *Ultrasonics Sonochemistry* by research teams from Qinghai University and Tsinghua University, a suspended-sediment sono-electrocoagulation experimental platform was built. The PIV platform consists of a high-speed camera, laser light source, synchronizer, and related software; the study used a Revealer PIV high-speed camera together with the PIV flow measurement software RFlow4 to acquire and analyze particle motion images, combined with particle size analysis and zeta potential measurements to investigate the flocculation process.
Figure 4 compares the velocity distributions at 900 s under eight typical operating conditions. With the electric field applied alone, bubbles generated near the electrode rise and drive circulatory flow; with the acoustic field applied alone, the flow direction and local velocities show different spatial distributions. After sono-electrocoagulation coupling, the extent of high-velocity regions and the flow structure change further, enabling differences between operating conditions to be compared within the same measurement plane.
The flow-field results also provide context for understanding flocculation performance. The study reported that under the coupled condition of 28 kHz and 40 A/m², the time-averaged flow velocity was 11.01 mm/s, the mean particle size increased from 18.89 μm to 60.98 μm, and the settling rate reached 87.96%. Meanwhile, at 77 kHz and 40 A/m², the time-averaged flow velocity was higher at 27.67 mm/s, yet the best flocculation performance appeared in the former. Combining vortex structures, particle size, and zeta potential results, the study attributed this difference to the balance between flow disturbance and floc stability.
Figure 4 — Flocculation flow fields of suspended sediment obtained with the Revealer PIV high-speed camera and PIV flow measurement software RFlow4, comparing velocity distributions and streamlines at 900 s across eight electric-field, acoustic-field, and coupled sono-electric operating conditions.
PIV here provides the flow environment in which particle transport occurs, while particle size and zeta potential measurements supplement information on aggregation state and surface charge. Only by bringing these results together can one further analyze why different external field conditions produce different flocculation and settling behaviors.
Many differences observed in heat and mass transfer research manifest not only as changes in interface morphology or macroscopic outcomes, but also in the way local flow is organized. The liquid displacement and vortex structures as a bubble approaches a surface, the redistribution of jet velocity under a gradient magnetic field, and the aggregation and settling of particles under sono-electric coupling occur in different systems, yet point to a common question: how does flow respond to changes in boundaries and external conditions, and how does it affect subsequent transport processes?
From process evolution in continuous imagery, to spatial distribution in velocity fields, and on to mutual corroboration with interface deformation, particle characteristics, and numerical computation, these studies progressively build the link between phenomena and mechanisms. Revealer high-speed imaging and PIV flow measurement systems provide direct and sufficient experimental evidence for capturing these transient processes, resolving local flow structures, and tracking their evolution.
English